Emerson-Fisher LP-Gas Equipment R232A-HBF Compact Integral 2-Stage Regulator, 9.5-13" W.C Spring, POL x 1/2" NPT


Emerson-Fisher LP-Gas Equipment R232A-HBF Compact Integral 2-Stage Regulator, 9.5-13" W.C Spring, POL x 1/2" NPT




Features
  • Body Sizes and End Connection Styles (inlet x outlet): FPOL x 1/2-inch FNPT
  • Maximum Allowable Inlet Pressure : 250 psig / 17,2 bar
  • Outlet Pressure Ranges : 10.2 – 13 inches W.C / 25 – 32 mbar
  • Capacity : 550,000 BTU/hr
  • Vent Size : 1st Stage : 7/16-24 Inverted Flare | 2nd Stage : 3/8 NPT screened
  • Emerson-Fisher LP-Gas Equipment R622-DFF 2nd Stage Regulator, 9-13" W.C Spring, 3/4" x 3/4" NPT





    Features
  • Body Sizes and End Connection Styles (inlet x outlet): 3/4 x 3/4-inch FNPT
  • Maximum Inlet Pressure: 10 psig / 0,69 bar : Emergency Inlet Pressure: 50 psig / 3,4 bar
  • Outlet Pressure Ranges : 9 to 13-inches W.C / 22 to 32 mbar
  • Capacity : 1,400,000 BTU/hr
  • Vent Size : 3/4 NPT screened
  • Emerson-Fisher LP-Gas Equipment R632A-JFF Integral 2-Stage Regulator, 9-13" W.C Spring, POL" x 3/4" NPT





    Features
  • Body Sizes and End Connection Styles (inlet x outlet): FPOL x 3/4-inch FNPT
  • Maximum Allowable Inlet Pressure : 250 psig / 17,2 bar
  • Outlet Pressure Ranges : 9 to 13-inches W.C / 22 to 32 mbar
  • Capacity : 850,000 BTU/hr
  • Vent Size : 1st Stage : 7/16-24 Inverted Flare | 2nd Stage : 3/4 NPT screened
  • Emerson-Fisher LP-Gas Equipment R622-BCF 2nd Stage Regulator, 9-13" W.C Spring, 1/2" x 1/2" NPT





    Features
  • Body Sizes and End Connection Styles (inlet x outlet): 1/2-inch x 1/2-inch NPT
  • Maximum Inlet Pressure: 10 psig / 0,69 bar : Emergency Inlet Pressure: 50 psig / 3,4 bar
  • Outlet Pressure Ranges : 9 to 13-inches W.C / 22 to 32 mbar
  • Capacity : 875,000 BTU/hr
  • Vent Size : 3/4 NPT screened
  • Emerson-Fisher LP-Gas Equipment R622H-DGJ 1st Stage Regulator, 8-12 psig Spring, 3/4" x 3/4" NPT





    Features
  • Body Sizes and End Connection Styles (inlet x outlet): 3/4 x 3/4-inch FNPT
  • Maximum Allowable Inlet Pressure : 250 psig / 17,2 bar
  • Outlet Pressure Ranges : 8 to 12 psig / 0.55 bar to 0.82 bar
  • Capacity : 2,400,000 BTU/hr
  • Vent Size : 3/4 NPT screened
  • Emerson-Fisher LP-Gas Equipment R232A-HBF Compact Integral 2-Stage Regulator, 9.5-13" W.C Spring, POL x 1/2" NPT





    Features
  • Body Sizes and End Connection Styles (inlet x outlet): FPOL x 1/2-inch FNPT
  • Maximum Allowable Inlet Pressure : 250 psig / 17,2 bar
  • Outlet Pressure Ranges : 10.2 – 13 inches W.C / 25 – 32 mbar
  • Capacity : 550,000 BTU/hr
  • Vent Size : 1st Stage : 7/16-24 Inverted Flare | 2nd Stage : 3/8 NPT screened
  • Emerson-Fisher LP-Gas Equipment R652-DFF Second Stage Regulator, Back Mount, 3/4" x 3/4" NPT, 9"-13" W.C. Spring





    Features
  • Body sizes and end connection styles (inlet x outlet): 3/4 x 3/4-inch FNPT
  • Maximum inlet pressure: 10 PSIG / 0,69 bar : Emergency inlet pressure: 50 PSIG / 3,4 bar
  • Outlet pressure ranges : 9 to 13-inches W.C. / 22 to 32 mbar
  • Capacity : 1,000,000 BTU/Hr
  • Vent Size : 3/4 NPT screened
  • Emerson-Fisher LP-Gas Equipment R622H-JGJ 1st Stage Regulator, 8-12 psig Spring, POL x 3/4" NPT





    Features
  • Body Sizes and End Connection Styles (inlet x outlet): FPOL x 3/4-inch FNPT
  • Maximum Allowable Inlet Pressure : 250 psig / 17,2 bar
  • Outlet Pressure Ranges : 8 to 12 psig / 0.55 bar to 0.82 bar
  • Capacity : 2,250,000 BTU/hr
  • Vent Size : 3/4 NPT screened
  • Emerson-Fisher LP-Gas Equipment R632A-CFF Integral 2-Stage Regulator, 9-13" W.C Spring, 1/4" x 3/4" NPT





    Features
  • Body Sizes and End Connection Styles (inlet x outlet): 1/4 x 3/4-inch FNPT
  • Maximum Allowable Inlet Pressure : 250 psig / 17,2 bar
  • Outlet Pressure Ranges : 9 to 13-inches W.C / 22 to 32 mbar
  • Capacity : 950,000 BTU/hr.Weight With FPOL: 2.9 lbs
  • Vent Size : 1st Stage : 7/16-24 Inverted Flare | 2nd Stage : 3/4 NPT screened
  • Emerson-Fisher LP-Gas Equipment R632A-HCF Integral 2-Stage Regulator, 9-13" W.C Spring, POL" x 1/2" NPT





    Features
  • Body Sizes and End Connection Styles (inlet x outlet): FPOL x 1/2-inch FNPT
  • Maximum Allowable Inlet Pressure : 250 psig / 17,2 bar
  • Outlet Pressure Ranges : 9 to 13-inches W.C / 22 to 32 mbar
  • Capacity : 850,000 BTU/hr
  • Vent Size : 1st Stage : 7/16-24 Inverted Flare | 2nd Stage : 3/4 NPT screened